<description><![CDATA[<p>
	<strong>Message</strong>:</p>
<p>
	We have had our spar for 3 years now.&nbsp; Recently it throws a circuit and will not stay on.&nbsp; We have gone through and found that every thing works well until we connect the Balboa&nbsp;VS500Z circuit board to the flow through heater via the two nut assemblies.&nbsp; Can you tell me if it is the flow through heater that needs to be replaced?&nbsp; If so what would be the part number and&nbsp;cost of this item?&nbsp; The information on the heater is &quot;5.5Kw 15&quot; 2x2 M7 w/stud, E188744&quot;.&nbsp; If additional information is required please let me know.&nbsp; Any advise you can provide would be appreciated.&nbsp; Thank you!</p>
<p>
	Dated on : 31-08-2011<br />
	&nbsp;</p>
<div style="width: 100%; height: 1px; border-bottom-color: rgb(102, 102, 102); border-bottom-width: 1px; border-bottom-style: solid;">
	&nbsp;</div>
<p>
	<strong>Replies :</strong></p>
<p style="background-color: rgb(255, 255, 255);">
	&nbsp;<br />
	If the breaker flips back immediately, then it is one of two things.</p>
<p>
	<br />
	1) Most common the GFCI wiring isn&#39;t right</p>
<p>
	<br />
	2) there is something wrong with the heater element</p>
<p>
	<br />
	Since this is a used&nbsp;spa pack, I suspect it is the later.&nbsp; See the attachment which discusses how to track down a ground fault.&nbsp; Very quickly, 1st undo the copper strips that connect to the heater element and bend the strips back so they don&#39;t touch anything.&nbsp; Try again.&nbsp; If the breaker still trips immediately it is the GFCI wiring.&nbsp; If it stops tripping then unfortunately it is the heating element and it needs to be replaced.</p>
<p>
	Dan</p>
<p>
	Post By : Dan Jung Dated On : 08-09-2011</p>